Slow delivery kills study momentum, which is why Prep4SureReview does not make you wait 24 hours like some vendors. Payment clears, and the complete EMC Dell PowerEdge Professional package with DCPPE-200 practice questions hits your inbox in about a minute.
EMC DCPPE-200 Exam Overview:
| Certification Vendor: | Dell Technologies (Dell EMC Proven Professional) |
|---|---|
| Exam Name: | Dell PowerEdge Professional Exam |
| Exam Number: | DCPPE-200 |
| Real Exam Qty: | 55 |
| Passing Score: | 700 (out of 900) |
| Available Languages: | English |
| Exam Format: | Scenario based, Multiple choice |
| Certificate Validity Period: | 2 years recertification policy |
| Related Certifications: | Dell Certified Associate – PowerEdge (DCAPE-100) |
| Exam Price: | Approximately USD 230 (varies by region) |
| Exam Duration: | 80 minutes |
| Sample Questions: | ![]() |
| Exam Way: | Proctored exam administered via Pearson VUE testing centres or OnVUE online proctoring. |
| Pre Condition: | Recommended experience: hands-on experience deploying/managing PowerEdge modular infrastructure (e.g., M1000e, VRTX, FX platforms). |
| Official Syllabus URL: | https://www.pearsonvue.com/us/en/dell.html |
EMC DCPPE-200 Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| PowerEdge Professional Exam Domains | - Networking & Connectivity
|
Frequently Asked Questions: EMC DCPPE-200 Exam
EMC Dell PowerEdge Professional is an official certification exam from Dell Technologies (Dell EMC Proven Professional), identified by the exam code DCPPE-200. Pass it and you hold the EMC Certification certification, which sits at the Professional level. It also feeds into related credentials, including Dell Certified Associate – PowerEdge (DCAPE-100). In practical terms, this certification tells employers your skills have been measured against the vendor's own standard, which is why certified candidates tend to stand out in hiring and promotion decisions.
Expect 55 questions within 80 minutes on the EMC Dell PowerEdge Professional exam. Numbers aside, the real challenge is rhythm: lingering too long on one item quietly steals time from three others. Build the habit of answering, flagging, and moving on, then rehearse the full experience under a countdown with the Prep4SureReview test engine until finishing comfortably early becomes your norm.
Registration for EMC Dell PowerEdge Professional officially runs Approximately USD 230 (varies by region), with 700 (out of 900) required to pass. Worth knowing before you book: retakes are billed at the same full Approximately USD 230 (varies by region), so a failed attempt doubles your spend. The smarter sequence is to measure yourself first. When your scores on the Prep4SureReview practice tests clear the passing line with room to spare, consistently, that is your signal to schedule the real thing.
Recommended experience: hands-on experience deploying/managing PowerEdge modular infrastructure (e.g., M1000e, VRTX, FX platforms).
Because vendors update their policies without much fanfare, verify the latest entry requirements before you book using the official exam page.
Yes, and we encourage it. Download the free PDF demo of the EMC Dell PowerEdge Professional questions from Prep4SureReview and evaluate the quality on your own terms. After you buy, every update for the next 365 days is free, and when that window closes you can extend your update service at half price.
A 100% money-back guarantee applies, governed by clear conditions. If you sit the EMC Dell PowerEdge Professional exam within 60 days of purchase and fail, you can claim a full refund, as long as the exam corresponds to your product. Attempts made within 3 days of purchase are ineligible, as are products you downloaded but never used, free materials, and expired orders; the name on the exam record must match the payer's name. File your claim with a scanned enrollment slip and the official Score Report PDF within 2 days of the exam, and it is settled within 7 days. Rather have a replacement than a refund? You may exchange for two other exam products of equal value, free, and your original product keeps its update service.
Delivery is essentially instantaneous: files unlock for download at payment and arrive in your email within one minute. Some vendors make you wait a day; if 2 hours pass here without delivery, check spam and contact customer service. Install on as many computers as you like, with no restrictions.
The EMC Dell PowerEdge Professional blueprint spans 1 domains. The ones carrying the most weight include PowerEdge Professional Exam Domains. The complete domain-by-domain breakdown is in the exam topics section above; treat it as your master checklist and let the weights tell you where your study hours earn the most.
EMC Dell PowerEdge Professional Sample Questions:
An engineer needs to configure a full height blade server and iSCSI traffic. The blade has two dual port NDCs.
The M1000e chassis only has switches in A fabric.
A1 - Production traffic:
174.1.0.0/16 network
Server facing switch ports use tagged VLANs 10, 30, 50
A2 - iSCSI traffic:
10.0.0.0/24 network
Untagged traffic
Switch is set to access VLAN 20
The engineer needs to set up the host to operate on the iSCSI network using two ports.
Which ports should be used?
- A. Use NIC port 2 and 4 together for iSCSI
- B. Use NIC port 1 and 4 together for iSCSI
- C. Use NIC port 3 and 4 together for iSCSI
- D. Use NIC port 1 and 3 together for iSCSI
Correct Answer: A 🗳️
An engineer has the following configuration:
* The data center is supplied with power from two independent external sources.
* Power distribution units (PDUs) on the left of the rack are wired to one power source. PDUs on the right are wired to the other source
* Chassis are fully populated with Power Supply Units (PSUs)
How should chassis power be configured for maximum availability?
- A. Starting with PSU1, plug the first half of power supplies into the left PDU, the remaining into the right PDU, and set Grid Redundancy in CMC.
- B. Plug half of the PSUS into the left Power Distribution Unit (PDU), plug the remainder of the PSUs into the right PDU, and set Max Power Conservation Mode in CMC.
- C. Starting with PSU1, plug odd numbered PSUs into the left PDU, plug even numbered PSUs into the right PDU, and set Redundancy Policy to Power Supply Redundancy
- D. Plug the first PSU into the left PDU, plug the remaining PSUs into the right PDU, and set Grid Redundancy in CMC.
Correct Answer: A 🗳️
An engineer is running an inventory report on a VRTX chassis group for a customer. When the engineer views the report, the engineer notices the inventory of one of the VRTX is missing one of its nodes.
What is the cause?
- A. The VRTX group member is in Chassis Power State Off since the node was inserted.
- B. The node's iDRAC is unreachable from the VRTX group leader's CMC.
- C. The VRTX group member is disconnected from the network at the time of the report.
- D. The node's iDRAC needs to have an Enterprise license installed.
Correct Answer: B 🗳️

Refer to the exhibit.
An engineer has installed a PCle NIC into an FX2 chassis. When the engineer powers up the blade, the NIC is not seen. Without physically moving the PCle NIC or server, how should the engineer make sure that the NIC maps to the server?
- A. Change the PCle Mapping to the correct server
- B. Enable PCle Slot Reassignment in the CMC
- C. Modify the PCle Mapping settings in the BIOS
- D. Change Virtual Slot setting for the server
Correct Answer: D 🗳️
Network A is on VLAN 10. Network B is on VLAN 20.
Physical environment
- Chassis is uplinked to top of rack switch
Switch configuration
- The uplink is untagged on VLANs 10
- Port 1 of server A on the fabric is untagged on VLAN 10
- Port 1 of server B on the fabric is untagged on VLAN 10
Customers on network B must be able to connect to server B but NOT A.
Network A needs to connect to servers A and B.
Which three changes must be made to meet this requirement? (Choose three.)
- A. Port 2 of server B needs to be untagged VLAN 20.
- B. The uplink needs to be trunked for VLAN 20.
- C. Port 1 of server B needs to be untagged VLAN 20.
- D. Port 2 of server A needs to be untagged VLAN 20.
- E. Port 1 of server A needs to be untagged VLAN 20.
- F. The uplink needs to be trunked for VLAN 10.
Correct Answer: C,D,F 🗳️
Viewing page 1 out of 19 pages.
Viewing questions 1-5 out of 93 questions.







