Prepare NCSC-Level-1 Question Answers - NCSC-Level-1 Exam Dumps
Real Nutanix NCSC-Level-1 Exam Questions [Updated 2022]
NEW QUESTION 29
What is the minimum number of nodes required for a Nutanix Cluster to support Replication Factor 3 (RF3) on a storage container?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION 30
A consultant configures an ESXi cluster which will utilize a vSphere Distributed Switch (vDS). The consultant has just migrated the first host to the dvSwitch when several alerts appear within Prism Element regarding Host-to-CVM connectivity.
What is causing these alerts?
- A. The consultant migrated the CVM Backplane network adapter over to the vDS.
- B. The consultant migrated the CVM Backplane and VM network adapter over to the vDS.
- C. VLAN tags are incorrectly configured on the vDS port groups.
- D. The consultant migrated the CVM svm-iscsi-pg network adapter over to the vDS.
Answer: A
NEW QUESTION 31
A consultant is using a customer's switch for installation. Although the 10GbE ports for each of the hosts are connected to the switch, the nodes fail to be discovered.
What is causing the issue?
- A. IPv6 is not enabled on the switch.
- B. IPMI port is not plugged in.
- C. Foundation VM is running on a Windows host.
- D. 10GbE ports are configured with the incorrect duplex setting.
Answer: A
NEW QUESTION 32
A consultant has deployed a new Nutanix AHV cluster with Foundation. The customer requests separating the management and production traffic in the CVM.
Which feature should the consultant configure?
- A. Micro-segmentation
- B. VLAN Tagging
- C. Network Segmentation
- D. Multi-homing
Answer: D
NEW QUESTION 33
A consultant successfully completes a Foundation using a flat switch. The consultant then works with the customer to move the cluster over to their production network. After the move, the CVMs and hypervisors can no longer communicate, which prevents the cluster from starting.
Which option should be used to resolve this issue?
- A. If the IPMI is in use, check that the IPMI can ping the default gateway over IPv6.
- B. Make sure that the IPMI and CVM VLAN is manually tagged on the Host and CVM.
- C. If using VLANs, confirm the hypervisor/CVM VLAN is set as Native on the switch ports.
- D. Verify that IPv6 Link Local and DHCP is enabled on all switch ports.
Answer: C
NEW QUESTION 34
A consultant is imaging a Nutanix cluster with VMware ESXi. Foundation returns an error that the media is not a supported ISO. The consultant checks the whitelist file in Foundation and confirms that the version of the ISO is not listed.
Which three actions should the consultant take to resolve this issue? (Choose three.)
- A. Obtain the MD5 checksum of the ISO and confirm MD5 checksum of ISO is listed.
- B. Download the iso_whitelist.json from the Support portal.
- C. Edit the whitelist file in Foundation.
- D. Restart the imaging process in Foundation.
- E. Replace and save whitelist file in Foundation
Answer: A,B,E
NEW QUESTION 35
A consultant is using the Foundation applet to create a cluster. During the process the consultant refreshes the progress bar web page and is concerned when nothing loads.
What should the consultant do to verify that Foundation has completed successfully?
- A. Return to the Foundation configuration page and start over.
- B. Update Java on the Foundation VM.
- C. Restart the Foundation process.
- D. Connect to any CVM IP address from a web browser.
Answer: D
NEW QUESTION 36
While preparing for a new four-node cluster installation, the consultant has a Tech Review Call with the customer. The hardware is as follows:
* 4 nodes in 1 Block
* 8 x 10 GbE Ports
* 4 x 1 GbE IPMI Ports
* Adequate Ethernet ports are available
* Ethernet cables are correct and available
* Adequate rack space is available
Which remaining item must be confirmed as available onsite?
- A. Fibre Channel switches
- B. Crash Cart
- C. Redundant 110v power
- D. Redundant 208v power
Answer: D
NEW QUESTION 37
A consultant creates three storage containers (container-1, container-2, container-3). The customer requires that only container-1, which will be utilized as an NFS datastore, be presented to external hosts.
However, users are able to mount all three containers.
What is causing this problem?
- A. A Container-level whitelist entry was configured.
- B. Compression was turned on for all containers.
- C. A Global whitelist entry was configured.
- D. Deduplication was turned on for all containers.
Answer: C
NEW QUESTION 38
In a 20-node ESXi deployment, the customer needs additional resiliency to survive the loss of two nodes concurrently.
Which configuration should the consultant use to ensure that the appropriate resources are available?
- A. Storage reservation for 10%; HA admission control for 10%, cluster RF2
- B. Storage reservation for 5%; HA admission control for 5%, cluster RF3
- C. Storage reservation for 10%; HA admission control for 10%, cluster RF3
- D. Storage reservation for 5%; HA admission control for 5%, cluster RF2
Answer: C
NEW QUESTION 39
A consultant is setting up a new Hyper-V cluster. The customer requirements are as follows:
* VMs should automatically failover to another host if the host crashes
* Host CPU and Memory resources should be evenly balanced
* New VMs should be placed on the host with the most resources available Which two Hyper-V features can be used to meet the requirements? (Choose two.)
- A. Failover Clustering
- B. Distributed Resource Scheduler
- C. Performance Resource Optimization
- D. High Availability
Answer: A,C
NEW QUESTION 40
Which Nutanix feature creation is described in the Knowledge Transfer?
- A. Calm Blueprints
- B. REST API
- C. Self Service Portal
- D. Data Protection Domain
Answer: D
NEW QUESTION 41
A Nutanix cluster has 10TB usable storage. The customer wants to create a 100GB datastore for ISO images to eliminate too much storage being consumed by unnecessary images.
Which setting should be used to accomplish this goal?
- A. From Container Advanced Settings, configure 100GB for advertised capacity.
- B. From Container Advanced Settings, configure 100GB for reserved capacity.
- C. From Container Advanced Settings, turn on compression and deduplication.
- D. From Container Advanced Settings, enable erasure coding.
Answer: A
NEW QUESTION 42
A consultant deploys a four-node VMware ESXi cluster and vCenter server. An HA/DRS cluster is configured for all four nodes. The customer deploys five new VMs on the cluster.
During the knowledge Transfer, a network cable on one node is removed to demonstrate HA and migration of the VMs to another host. In the HA/DRS cluster settings, the VM Restart Priority for all CVMs is set to Disabled. The customer observes warnings that the CVM on the ejected host is no longer powered on.
Which ESXi HA/DRS cluster setting is missing?
- A. Disable VM Monitoring on all CVMs.
- B. Enable EVC for the cluster.
- C. Enable Host Monitoring.
- D. Disable Automation Level on all CVMs.
Answer: D
NEW QUESTION 43
Where in the Support Portal is the Best Practices guide for vSphere Networking located?
- A. Knowledge Base
- B. Product Notices
- C. Software Documentation
- D. Solutions Documentation
Answer: D
NEW QUESTION 44
During the Foundation imaging process, nodes are successfully imaged, but the cluster creation fails.
Which log should the consultant review to determine the cause?
- A. genesis.out
- B. service.log
- C. first_boot.log
- D. foundation.out
Answer: B
NEW QUESTION 45
A consultant successfully installs the Foundation VM on a laptop and needs to ensure the VM can communicate externally.
Which two configuration changes should the consultant make next? (Choose two.)
- A. Configure the static IP address through the desktop virtualization software.
- B. Open terminal and configure via ifconfig command.
- C. Ensure the vNIC is set to bridged adapter.
- D. Run the set_foundation_ip_address application on the VM desktop.
Answer: C,D
NEW QUESTION 46
......
NCSC-Level-1 Exam Dumps Pass with Updated 2022: https://www.prep4surereview.com/NCSC-Level-1-latest-braindumps.html