The BICSI DCDC-002 (BICSI Data Center Design Consultant - DCDC) Certification Exam is designed for individuals who are looking to demonstrate their expertise in designing data centers. This certification exam is ideal for professionals who are involved in the design, installation, and maintenance of data centers. The BICSI DCDC-002 exam covers a range of topics, including data center design, electrical systems, cooling systems, fire suppression systems, and security.
The BICSI DCDC-002 (BICSI Data Center Design Consultant - DCDC) Exam is a certification offered by the Building Industry Consulting Service International (BICSI). This certification is designed to recognize individuals who have the knowledge and skills necessary to design and implement data center infrastructure. The exam covers a wide range of topics including data center design, power and cooling, security, and network infrastructure.
NEW QUESTION # 87
What is the low temperature that must be maintained in a data center according to NEB standards?
- A. 55 degrees
- B. 75 degrees
- C. 70 degrees
- D. 60 degrees
- E. 65 degrees
Answer: E
NEW QUESTION # 88
According to NEB, what is the recommended range for the low temperature in a data center?
- A. 55 degrees
- B. 75 degrees
- C. 70 degrees
- D. 60 degrees
- E. 65 degrees
Answer: E
NEW QUESTION # 89
What is the recommended height of a ceiling in a data center or telecommunications room?
- A. 0
- B. 1015ft(correct)
- C. 012 ft
- D. 1112ft
Answer: B
NEW QUESTION # 90
what additional fuel filtering is required for generators in class F3 and F4 facilities
- A. five stage, mesh type fuel filters
- B. two-stage, spin-on-type fuel filters
- C. three stage, spin-on-type fuel filters
- D. four stage, paper-type fuel filters
Answer: C
NEW QUESTION # 91
Where should power cable be ran in an access floor?
- A. Below the access floor
- B. Above the access floor
- C. Cold aisle
- D. Hot aisle
Answer: C
NEW QUESTION # 92
what is typical entrance room power requirement?
- A. 500, to 1500 watts per access provider
- B. More than about Million watts
- C. exactly or less than 300KW
- D. More than 2000 KW
Answer: A
NEW QUESTION # 93
What's conservative' hydrogen maximum flow rate per minute for battery.
- A. None of these answer
- B. 61 cm/m²
- C. 21 cm/m²
- D. 500 cm/m²
Answer: C
NEW QUESTION # 94
What is the NEBS GR-3028-CORE recommended operational temperature.
- A. -20°F/-28° C minimum and up to a maximum of104 ° Fahrenheit/40° Celsius
- B. -25°F to +125°F (-32°C to +52°C)
- C. Up To140 Degrees Fahrenheit /60 Degrees Celsius
- D. -30°F to +110°F (-34°C to +43°C)
Answer: A
NEW QUESTION # 95
What are the factors that affect availability?
- A. All of the above
- B. Operational Availability
- C. Operational Requirements
- D. Impact of Downtime
Answer: A
NEW QUESTION # 96
What is the minimum height of a ceiling in a data center or telecommunications room?
- A. twelve feet from finished floot to pay constructionjssgspritesari sek
- B. Five feet from finished floor to any obstruction, sprinklers, lighting
- C. ten feet from finished foroor to asany oos obstruction, sprinklers, lighting(correct)
- D. eight feet from finished floor to any obstruction, sprinklers, lighting
Answer: C
NEW QUESTION # 97
What electrical service feed options are there for a data center?
- A. Single Entrance/Single Pathway
- B. All of the above
- C. Single Entrance/Dual Pathway
- D. Dual Entrance/Dual Pathway
Answer: B
NEW QUESTION # 98
What is the Fourth Preference Regarding Utility Service?
- A. At least four circuits each from different distribution stations but fed via common feeders
- B. At least two circuits from one substation fed via alternative power grid
- C. One circuit from one substation, separate paths
- D. Two balanced feeds with different voltages derived from a single distribution station
Answer: C
NEW QUESTION # 99
What is the typical air delivery temperature from a CRAC unit?
- A. 20-25 degrees Celsius
- B. 13-16 degrees Celsius
- C. 10-13 degrees Celsius
- D. 15-18 degrees Celsius
Answer: B
NEW QUESTION # 100
What is the minimum distance recommended between a data center's backup generator and the main data center building?
- A. 40 feet
- B. 30 feet
- C. 10 feet
- D. 20 feet
Answer: B
NEW QUESTION # 101
where should engineering offices be located?
- A. far away from the data center
- B. adjacent to equipment rooms they support
- C. in a separate building
- D. inside computer room
Answer: B
NEW QUESTION # 102
Why are H DAs more often required in data centers?
- A. they avoid cable congestion
- B. they improve fire suppression system
- C. they enhance cooling effectiveness
- D. they minimize noise pollution
Answer: A
NEW QUESTION # 103
How far should Data Center be located from Commercial Airport?
- A. At Least 3 Miles
- B. At least 10 miles
- C. None of the above.
- D. At Least 5 Miles
Answer: D
NEW QUESTION # 104
......
The certification exam covers a wide range of topics related to data center design, including power and cooling systems, fire suppression, security, cabling infrastructure, and more. Candidates are required to demonstrate their knowledge of industry standards and best practices for data center design, as well as their ability to apply this knowledge to real-world scenarios. The exam is designed to be challenging, but fair, and is based on a rigorous set of criteria that has been developed by industry experts.